Intel® Stratix® 10 Clocking and PLL User Guide

ID 683195
Date 9/08/2023
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

6.3. Dynamic Phase Shift Ports in the IOPLL IP Core

Figure 30. Dynamic Phase Shift Port Ports in the IOPLL IP Core
Table 18.  Dynamic Phase Shift Ports in the IOPLL IP Core
Port Direction Description
scanclk Input Dynamic phase shift clock that drives the IOPLL IP core dynamic phase shift operation. This port must be connected to a valid clock source. The maximum input clock frequency is 100 MHz.
phase_en Input Active high signal. Asserts to start the dynamic phase shift operation. phase_en can only be asserted 4 clocks after phase_done assertion.
updn Input Determines the direction of dynamic phase shift. When updn = 0, phase shift is in negative direction. When updn = 1, phase shift is in positive direction.
cntsel[4..0] Input
Determines the counter to be selected to perform dynamic phase shift operation.
Counter Name cntsel[4..0] (Binary)
C0 5’b00000
C1 5’b00001
C2 5’b00010
C3 5’b00011
C4 5’b00100
C5 5’b00101
C6 5’b00110
C7 5’b00111
C8 5’b01000
All C counters 5’b01111
num_phase_shift[2..0] Input Determines the number of phase shifts per dynamic phase shift operation. Up to seven phase shifts per operation are possible. Each phase shift step is equal to 1/8 of I/O PLL VCO period. num_phase_shift must never be set to 0 in DPS mode.
phase_done Output The IOPLL IP core drives this port high for one scanclk cycle after dynamic phase shift operation is complete.